Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
Odovtos (En linea) ; 25(1)abr. 2023.
Article in English | LILACS, SaludCR | ID: biblio-1422190

ABSTRACT

Dental fluorosis can cause changes in the enamel surface, conditioning its functionality and esthetics. The application of dental adhesives is a treatment option; however, their use on fluorotic teeth can result in limitations. The aim of this study was to compare the shear bond strength of two different adhesives, one with 10-MDP and one without 10-MDP, in different degrees of dental fluorosis.This is an in vitro study on dental enamel samples, a total of 180 samples with the inclusion criteria were treated, randomly divided into two groups of 90, according to the type of dental adhesive, where each group was again divided into three groups of 30 samples, representing different degrees of dental fluorosis according to the Thylstrup-Fejerskov index (Group I: TF1 and TF2; Group II: TF3; Group III: TF4). Normality tests, two-factor ANOVA, and post-hoc tests were used to determine differences between the groups, with a significance level of 95%. As results, a statistically significant difference was shown between the use of dental adhesive with 10-MDP and the three groups of dental fluorosis (p=0.011), in addition, a Tukey post-hoc test on the groups treated with 10-MDP adhesive revealed a statistically significant difference between group I versus group II, and group I versus group III, (p=<0.05). It is concluded that the use of adhesive systems with 10-MDP presents a better shear bond strength on enamel with dental fluorosis grades I and II in the Thylstrup-Fejerskov index.


La fluorosis dental puede ocasionar cambios en la superficie del esmalte, condicionando su funcionalidad y estética, la aplicación de adhesivos dentales es una opción de tratamiento, sin embargo, su uso en dientes fluoroticos puede resultar en limitaciones. El objetivo de este estudio consistió en comparar la fuerza de adhesión a la cizalladura de dos diferentes adhesivos, uno con 10-MDP y otro sin 10-MDP, en diferentes grados de fluorosis dental. Se trata de un estudio in vitro en muestras de esmalte dental, un total de 180 muestras con los criterios de inclusión fueron tratadas, aleatoriamente divididas en dos grupos de 90, de acuerdo al tipo de adhesivo dental, donde cada grupo fue dividido nuevamente en tres grupos de 30 muestras, representando diferentes grados de fluorosis dental según el índice de Thylstrup- Fejerskov (Grupo I: TF1 y TF2; Grupo II: TF3; Grupo III: TF4). Para determinar diferencias entre los grupos se utilizaron pruebas de normalidad, ANOVA de dos factores, y pruebas post-hoc, con un nivel de significancia de 95%. Como resultados, se mostró una diferencia estadísticamente significativa entre el uso de adhesivo dental con 10- MDP y los tres grupos de fluorosis dental (p=0.011), además, una prueba post hoc de Tukey sobre los grupos tratados con adhesivo 10-MDP revelaron una diferencia estadísticamente significativa entre el grupo I frente al grupo II, y el grupo I frente al grupo III, (p=<0.05) Se concluye que el uso de sistemas adhesivos con 10-MDP presentan una mejor resistencia de adhesión al cizallamiento en esmalte con grados de fluorosis dental I y II en el índice de Thylstrup-Fejerskov


Subject(s)
Dentin-Bonding Agents/therapeutic use , Fluorosis, Dental/diagnosis , Resin Cements
2.
Braz. dent. sci ; 26(1): 1-9, 2023. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1411424

ABSTRACT

Objective: Evaluate the mechanical properties of experimental adhesive models with different photoinitiators (PI) polymerized by LED units of different power densities. Material and Methods: Three groups of adhesive models based on HEMA/BisGMA (45/55) were prepared in association with different PI combinations: G2 (control) ­ 2 PI: 0.5% CQ, 0.5% EDMAB; G3 - 3 PI: 0.5% CQ; 0.5% DMAEMA, 0.5% DPIHP; G4 - 4 PI: 0.5% CQ; 0.5% EDMAB; 0.5% DMAEMA; 0.5% DPIHP. The three formulations were polymerized at two different LED power densities: 550 mW/cm2 and 1200 mW/cm2. The degree of conversion (DC) of adhesive monomers was monitored in situ through the FTIR for 600 s. Specimens were prepared for each formulation for analysis mong adhesive systems (G2

Objetivo: Avaliar as propriedades mecânicas de modelos adesivos experimentais com diferentes fotoiniciadores (PI) polimerizados por unidades de LED de diferentes densidades de energia. Material e Métodos: Três grupos de modelos adesivos baseados em HEMA/BisGMA (45/55) foram preparados em associação com diferentes combinações de PI: G2 (controle) ­ 2 PI: 0,5% CQ, 0,5% EDMAB; G3 - 3PI: 0,5% CQ; 0,5% DMAEMA, 0,5% DPIHP; G4 - 4 PI: 0,5% CQ; 0,5% EDMAB; 0,5% DMAEMA; 0,5% DPIHP. As três formulações foram polimerizadas em duas densidades de potência de LED: 550 mW/cm2 e 1200 mW/cm2. O grau de conversão (DC) dos monômeros adesivos foi monitorado in situ através do FTIR durante 600 s. Amostras foram preparadas para cada formulação para análise de resistência à flexão (FS), módulo de elasticidade (ME), sorção (SOR) e solubilidade (SOL). Os dados foram submetidos aos testes ANOVA 2-fatores e Tukey (5%). Resultados: DC: houve diferença significativa entre os sistemas adesivos (G2

Subject(s)
Radiation , Dentin-Bonding Agents , Light-Curing of Dental Adhesives , Photoinitiators, Dental
3.
Rev. ADM ; 79(5): 284-291, sept.-oct. 2022. tab
Article in Spanish | LILACS | ID: biblio-1428520

ABSTRACT

Introducción: se realizó una revisión bibliográfica con el objetivo de conocer, analizar y comparar los diferentes tipos de adhesivos de octava generación que se encuentran en el mercado y la diferencia que existe entre cada uno. Los adhesivos universales han demostrado mejoras en su resistencia, sobre todo en las técnicas de aplicación y en las propiedades de estos materiales, al mejorar la fuerza adhesiva para que el odontólogo pueda brindar tratamientos restaurativos exitosos. Objetivo: conocer, analizar y comparar los diferentes tipos de adhe- sivos de la octava generación empleados en odontología. Material y métodos: se realizó una búsqueda en las bases de datos electrónicas PubMed, BVS, Redalyc y ScienceDirect. Se utilizaron 32 artículos que cumplieron con los criterios predeterminados y la especificidad reque- rida para la pregunta de investigación. Conclusiones: se demostró que la tecnología cada día avanza, sobre todo en el área de los adhesivos, ya que éstos son de mucha utilidad en el día a día del odontólogo; es importante conocer cada uno de éstos, puesto que es un poco complejo seleccionar el correcto, mas no el uso. En la actualidad, existen diversas opciones por las que el odontólogo puede optar, es por ello que el pro- fesional debe estar capacitado sobre cada una de las diferentes marcas existentes y, de acuerdo al tratamiento, debe elegir cuál es mejor utilizar en una rehabilitación. Es importante para el odontólogo conocer estos materiales, ya que esto lo beneficiará al momento de llevar un plan de tratamiento restaurador (AU)


Introduction: a bibliographic review was carried out to learn about, analyze, and compare the different types of eighth-generation adhesives on the market and the difference between each one. Universal adhesives have demonstrated improvements in their resistance, especially in the application techniques and properties of these materials, improving the adhesive strength so that the dentist can provide successful restorative treatments. Objective: to know, analyze and compare the different types of eighth-generation adhesives used in dentistry. Material and methods: a search was made of the following electronic databases: PubMed, BVS, Redalyc, ScienceDirect. Finally, 32 articles that met the predetermined criteria and the specificity required for the research question were used. Conclusions: it was demonstrated that technology is advancing every day, especially in the area of adhesives since these are very useful in the daily life of the dentist. It is important to know each one of these since it is a little complex at the moment of selecting the correct one, but not the use. Currently, there are several options that the dentist can choose, which is why the professional must be trained on each of the various existing brands and according to the treatment which is the best to use at the time of rehabilitation. The dentist needs to know these materials since they will benefit him/her when carrying out a restorative treatment plan (AU)


Subject(s)
Technology, Dental/trends , Dentin-Bonding Agents , Surface Properties , Acid Etching, Dental/methods , Compressive Strength , Dental Enamel/drug effects , Shear Strength , Dentin/drug effects , Nanoparticles , Flexural Strength
4.
Braz. dent. sci ; 25(2): 1-10, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1367388

ABSTRACT

Objective: The aim of this study was to evaluate the effect of STMP as biomimetic analog of dentin matrix on the dentin bond strength submitted to artificial cariogenic challenge over time. Material and Methods: The total number of teeth used in the experiment was 60 teeth, which were divided into 6 groups (n = 10). Of these total amount, 10 teeth were not submitted to the artificial cariogenic challenge (ACC), serving as control group (Sound Dentin - SD) while the other 50 were submitted to an ACC (7d/37ºC), being treated with treatment solutions according to each group: SD- deionized water/sound dentin, CD- deionized water/ artificial caries dentin, GIII- STMP, GIV- STMP + Ca(OH)2, GV- STMP + NaF, and GVI- NaF. After treatments (24h), the specimens were restored (Adper Single Bond Universal + Filtek Z250), to obtain resin­dentin sticks with a cross sectional area of 0.8mm2, approximately. Two-third of these sticks were stored in artificial saliva (37°C) for analyzes after 6 and 12 months. The 1/3 remains were subjected to µTBS test (baseline). Data were analyzed by two-way ANOVA and Tukey tests (p<0.05). Results: In general, the highest µTBS values were obtained in sound condition (SD), while the artificial caries condition (CD) determined minimum values. Groups treated with NaF (with or without STMP- GV and GVI) were not able to improve adhesion over time. Only the use of STMP + Ca(OH)2(GIV) improved the µTBS compared to the others caries-challenged dentin after 1 year. The adhesive failure pattern was predominant in all time. Conclusion: The use of the STMP associated with Ca(OH)2 seems to be a viable therapeutic strategy conciliating the biomimetizing capacity to the adhesive process satisfactorily even its performance is not superior to initial condition (AU)


Objetivo: O objetivo deste estudo foi avaliar o efeito do STMP como análogo biomimético da matriz dentinária na resistência de união à dentina submetida a desafio cariogênico artificial ao longo do tempo. Material e Métodos:foram utilizados um total de 60 dentes neste experimento, os quais foram divididos em 6 grupos (n = 10). Desse total, 10 dentes não foram submetidos ao desafio cariogênico artificial (DCA), servindo como grupo controle (Dentina Hígida - DH) enquanto os outros 50 foram submetidos ao DCA (7d / 37ºC), sendo tratados com soluções de tratamento específicas para cada grupo: DH- água deionizada / dentina hígida, DC- água deionizada / dentina submetida ao DCA, GIII- STMP, GIV- STMP + Ca(OH)2, GV- STMP + NaF e GVI- NaF. Após os tratamentos (24h), os corpos-de-prova foram restaurados (Adper Single Bond Universal + Filtek Z250), para obtenção de palitos de resina-dentina com área transversal de aproximadamente 0,8mm2. Dois terços desses palitos foram armazenados em saliva artificial (37°C) para análises após 6 e 12 meses. Os outros 1/3 foram submetidos ao teste µTBS (baseline). Os dados foram analisados por ANOVA a dois fatores e testes de Tukey (p <0,05). Resultados:Em geral, os maiores valores de µTBS foram obtidos em condição hígidas (DH), enquanto a condição subtmetidas ao DCA determinou os menores valores. Os grupos tratados com NaF (com ou sem STMP associado -GV e GVI) não foram capazes de melhorar a resistência de união, ao longo do tempo. Somente o uso de STMP + Ca (OH)2(GIV) melhorou o µTBS em comparação com as outras condições desafiadas por cárie após 1 ano. O padrão de falha adesiva foi predominante em todos os tempos. Conclusão: O uso do STMP associado ao Ca (OH)2 parece ser uma estratégia terapêutica viável conciliando a capacidade biomimetizante ao processo adesivo de forma satisfatória mesmo que seu desempenho não seja superior à condição inicial.(AU)


Subject(s)
Humans , Protease Inhibitors , Dentin-Bonding Agents , Dentin
5.
Article | IMSEAR | ID: sea-192253

ABSTRACT

Context: Zinc-oxide eugenol (ZOE) is frequently used due to its satisfactory biological response, sedative effect on the pulp, and easy removal. However, literature is very controversial about the influence of the temporary cement-containing eugenol on the bond strength properties. Aims: This study aims to clarify the literature controversy by evaluating the bond strength of ZOE or ZOE-free applied before bonding procedures and the 7-day resting period after the first session. Settings and Designs: Twelve recently extracted third molars were randomly divided into three groups: Group 1: Control (without treatment), Group 2: Temp-Bond NE; Group 3: Temp-Bond. Subjects and Methods: After temporary restorations, the teeth were immersed in distilled water and stored for 7 days at 37°C. The temporary cement was mechanically removed, and prophylaxis was performed. The adhesive procedures were performed, and a 6-mm-high composite resin block was built. The teeth were immediately stored at 100% relative humidity at 37°C for 24 hours. Specimens with 0.7 (±0.2) mm2 of cross-sectional area were obtained and subjected to a microtensile bond strength (μTBS) test at 1 mm/min until failure. Statistical Analysis Used: Analysis of variance (ANOVA) and Tukey's post hoc test were used for statistical analysis. Results: ZOE or ZOE-free cement did not interfere in the μTBS between resin composite and dentine when used with a two-step-etch-rinse adhesive material, considering 7 days of resting period after the first session, by the ANOVA and Tukey's post hoc test (P < 0.05). Conclusions: The authors recommend the removal of the temporary cementation at least seven days after the first session and suggest that the clinicians follow-up further studies to use the cement in case its removal is recommended within a longer period.

6.
Annals of Dentistry ; : 1-7, 2019.
Article in English | WPRIM | ID: wpr-750390

ABSTRACT

@#The study aimed to evaluate the shear bond strength (SBS) and to analyse the failure mode at the resindentine interface of different dental adhesive systems. A total of 75 sound premolar teeth were selected and randomly assigned into five different adhesive groups (n=15): OptiBond Solo (OBS, total-etch), OptiBond Versa (OBV, two-bottles, self-etch), Adhe SE Ivoclar (ADHE, two-bottles, self-etch), G-Bond (GB, one-bottle, selfetch), and OptiBond All in One (OBO, one-bottle, self-etch). The occlusal surface of each tooth was flattened and composite resin cylinder (4x2 mm) was built up on the flat dentine surface using a custom made mould. The specimens were then subjected to 500 thermal cycles between 5 °C and 55 °C and dwell time of 20s. The SBS test was conducted using a universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed using one-way ANOVA and Dunnett T3 Test. Failure mode was determined as adhesive, cohesive or mixed mode using a stereomicroscope and the data were analyzed using Fisher's exact test. The total-etch (OBS) had significantly higher value of SBS than the two self-etch (ADHE and GB) adhesive systems. Within the self-etch systems, OBV showed significantly higher SBS value compared to ADHE and GB. There were no statistically significant differences between types of failure mode (p > 0.05) and adhesive group. It can be concluded that the different compositions in the self-etch adhesive materials may contribute to the different SBS value. The failure modes detected within all tested groups did not show clinically important differences

7.
Rev. odontol. mex ; 22(3): 160-164, jul.-sep. 2018. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1014415

ABSTRACT

RESUMEN Introducción: No existe un protocolo definitivo para la reparación de cerómeros. Los adhesivos universales debido a su composición e indicaciones pueden ser una alternativa dentro de la reparación de restauraciones poliméricas, pero la asociación de los silanos con los adhesivos universales requiere más investigación. Objetivo: Evaluar y comparar la resistencia de unión de dos adhesivos universales en la interfase cerómero-resina, asociado o no a un agente silano. Material y métodos: Se realizaron seis bloques de cerómero y se trataron según las siguientes variables: (A) sin tratamiento, (B) agente silano, (C) adhesivo universal 1 + silano, (D) adhesivo universal 1, (E) adhesivo universal 2 + silano, (F) adhesivo universal 2 (n = 10). Se unió resina compuesta a dichas superficies y se realizó prueba de microtensión. El tipo de falla se evaluó con estereomicroscopio. Resultados: Los valores de resistencia de unión de los grupos fueron estadísticamente diferentes (p < 0.05), excepto entre ambos adhesivos universales evaluados. El grupo B presentó los valores más altos de resistencia adhesiva. Los grupos C y E obtuvieron valores de resistencia adhesiva menores en comparación con los grupos D y F. El tipo de falla predominante fue el adhesivo. Conclusión: El uso asociado de un silano funcional con los adhesivos universales no mejora los valores de resistencia adhesiva, por lo que debería evitarse. Como primera elección se recomienda el silano funcional, y en segundo grado, sólo usar adhesivos universales, pero no asociar los dos materiales en un mismo proceso adhesivo.


ABSTRACT Introduction: There is no definitive protocol for ceromer repairs. Universal adhesives due to their composition and indications may be an alternative for polymeric restorations repair. But the association of silanes with universal adhesives requires more research. Objective: To evaluate and compare the bond strength of two universal adhesives in ceromer - resin interface, associated or not with a silane agent. Material and methods: Six ceromer blocks were made and treated according to the following variables: (A) No treatment, (B) Silane agent, (C) Universal Adhesive 1 + Silane, (D) Universal Adhesive 1, (E) Adhesive Universal 2 + Silane, (F) Universal Adhesive 2 (n = 10). Composite resin was attached to these surfaces and a microtension test was performed. The type of failure was evaluated with a stereomicroscope. Results: The bond strength values of the groups were statistically different (p <0.05), except between both universal adhesives were evaluated. Group (B) presented the highest values of adhesive resistance. Groups (C and E) had lower adhesive strength values compared to groups (D and F). The most prevalent type of failure was the adhesive. Conclusion: The associated use of functional silane to universal adhesives does not improve adhesive strength values, so it should be avoided. As a first choice, functionalsilane is recommended, and in the second degree, only use universal adhesives, but do not associate the two materials in the same adhesive process.

8.
Chinese Journal of Stomatology ; (12): 374-380, 2018.
Article in Chinese | WPRIM | ID: wpr-806629

ABSTRACT

The longevity of direct adhesive restoration is related to the restorative materials, the patient and the professional. On one hand, dental composites/adhesives have been modified and developed to fulfill the criteria for clinical application. On the other hand, the clinical guidelines for adhesive restorations have been released and updated accordingly, which would prolong the longevity of restorations. In this commentary, the removal of carious tissues, interface preparation for bonding and application of adhesives are emphasized. The administrative measures for registration and clinical evaluation criteria for adhesive restorative material are also introduced.

9.
West China Journal of Stomatology ; (6): 46-51, 2018.
Article in Chinese | WPRIM | ID: wpr-773298

ABSTRACT

OBJECTIVE@#This investigation aimed to develop a novel antibacterial dental adhesive containing nanoantibacterial inorganic fillers and measure the dentin bonding strength, mechanical properties, and antibacterial property of the novel adhesive in vitro.@*METHODS@#Novel nanoantibacterial inorganic fillers containing quaternary ammonium salt with long chain alkyl were synthesized on the basis of previous research. These novel nanoantibacterial inorganic fillers were added into the dental adhesive to prepare novel nanoantibacterial dental resin composite at mass fractions of 0%, 2.5%, 5.0%, 7.5%, and 10%; 0% was used as control. Dentin shear bonding test was used to evaluate the bonding strength. Flexural test was utilized to measure the novel resin composite flexural strength and elastic modulus. A dental plaque microcosm biofilm model with human saliva as inoculum was formed. Colony forming unit, lactic acid production, and live/dead assay of the biofilm on novel dental adhesive were calculated to assess the effect of novel dental adhesive on human dental plaque microcosm biofilm.@*RESULTS@#The dentin shear bond strength, flexural strength, and elastic modulus were 28.9 MPa, 86.6 MPa, and 4.2 GPa, respectively, when the nanoantibacterial inorganic filler mass fraction in the dental adhesive reached approximately 5.0%. Consequently, the dentin shear bond strength and mechanical properties significantly increased. Addition of 2.5% nanoantibacterial inorganic fillers into the dental adhesive exerted no adverse effect on the mechanical properties significantly (P>0.05). Dental adhesive containing 5% or more nanoantibacterial inorganic fillers inhibited the metabolic activity of the dental plaque microcosm biofilm significantly, thereby displaying a strong antibacterial potency (P<0.05).@*CONCLUSIONS@#This novel antibacterial dental adhesive, which contained 5.0% nanoantibacterial inorganic filler, exhibited promising bonding strength, mechanical property, and antibacterial ability. Hence, this adhesive can be potentially used in caries inhibition in dental application.


Subject(s)
Humans , Anti-Bacterial Agents , Biofilms , Dental Bonding , Dental Cements , Dental Plaque , Materials Testing , Methacrylates , Resin Cements , Shear Strength
10.
J. appl. oral sci ; 24(6): 555-560, Nov.-Dec. 2016. tab, graf
Article in English | LILACS, BBO | ID: biblio-841154

ABSTRACT

ABSTRACT Objective To evaluate the influence of phenyl-propanedione on yellowing and chemical-mechanical properties of experimental resin-based materials photoactivated using different light curing units (LCUs). Material and Methods Experimental resin-based materials with the same organic matrix (60:40 wt% BisGMA:TEGDMA) were mechanically blended using a centrifugal mixing device. To this blend, different photoinitiator systems were added in equimolar concentrations with aliphatic amine doubled by wt%: 0.4 wt% CQ; 0.38 wt% PPD; or 0.2 wt% CQ and 0.19 wt% PPD. The degree of conversion (DC), flexural strength (FS), Young’s modulus (YM), Knoop hardness (KNH), crosslinking density (CLD), and yellowing (Y) were evaluated (n=10). All samples were light cured with the following LCUs: a halogen lamp (XL 2500), a monowave LED (Radii), or a polywave LED (Valo) with 16 J/cm2. The results were analysed by two-way ANOVA and Tukey’s test (α=0.05). Results No statistical differences were found between the different photoinitiator systems to KNH, CLS, FS, and YM properties (p≥0.05). PPD/CQ association showed the higher DC values compared with CQ and PPD isolated systems when photoactivated by a polywave LED (p≤0.05). Y values were highest for the CQ compared with the PPD systems (p≤0.05). Conclusion PPD isolated system promoted similar chemical and mechanical properties and less yellowing compared with the CQ isolated system, regardless of the LCU used.


Subject(s)
Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Bisphenol A-Glycidyl Methacrylate/chemistry , Chalcones/chemistry , Light-Curing of Dental Adhesives/methods , Photoinitiators, Dental/chemistry , Spectrophotometry , Materials Testing , Camphor/analogs & derivatives , Camphor/chemistry , Reproducibility of Results , Spectroscopy, Fourier Transform Infrared , Prosthesis Coloring , Color , Statistics, Nonparametric , Pliability , Phase Transition , Curing Lights, Dental , Elastic Modulus , Polymerization , Hardness Tests
11.
Braz. dent. j ; 26(5): 474-477, Oct. 2015. tab, graf
Article in English | LILACS | ID: lil-767632

ABSTRACT

Abstract: The aim of this study was to evaluate the effect of silanization protocols on the bond strength of two resin cements to a lithium disilicate glass-ceramic. Thirty-two ceramic discs were assigned to 2 groups (n=16): G1 - dual-cured resin cement and G2 - light-cured resin cement. Four subgroups were evaluated according to the used silanization protocol. The glass-ceramic was etched with 10% hydrofluoric acid for 20 s and silane was applied for 1 min, as follows: CTL - according to the manufacturer's instructions; HA - dried with hot air; NWA - washed and dried with water and air at room temperature; HWA - washed and dried with hot water and hot air. Thereafter, adhesive was applied and light-cured for 20 s. Silicon molds were used to prepare resin cement cylinders (1x1 mm) on the ceramic surface. The specimens were stored in deionized water at 37 °C for 48 h and subjected to a micro-shear test. The data were submitted to statistical analysis (?#61537;=0.05). Group G1 showed higher bond strengths than G2, except for the CTL and NWA subgroups. Differences as function of the silanization protocol were only observed in G1: HWA (25.13±6.83)≥HA (22.95±7.78)≥CTL(17.44±7.24) ≥NWA(14.63±8.76). For G2 there was no difference among the subgroups. In conclusion, the silanization protocol affected the resin cement/ceramic bond strengths, depending on the material. Washing/drying with hot water and/or hot air increased only the bond strength of the dual-cured resin cement.


Resumo: O objetivo do estudo foi avaliar o efeito da técnica de silanização na resistência de união de cimentos resinosos a uma vitrocerâmica. Trinta e dois discos de vitrocerâmica foram distribuídos em 2 grupos (n=16) (G1: cimento dual e G2: cimento fotoativado) e subdivididos em 4 grupos de acordo com a técnica de silanização. A vitrocerâmica foi condicionada com ácido fluorídrico a 10% por 20 s e o silano aplicado por 1 min de acordo com os subgrupos: CTL: de acordo com as instruções do fabricante, HA: secagem do silano com ar quente, NWA: lavagem e secagem com água e ar a temperatura ambiente, HWA: lavagem e secagem com água e ar quente. Após, o sistema adesivo foi aplicado e polimerizado por 20 s, e cilindros (1 x 1 mm) foram confeccionados com os cimentos sobre a superfície da cerâmica. Os espécimes foram armazenados em água destilada por 48 h e submetidos ao ensaio de microcisalhamento. Os dados foram submetidos à análise estatística (?#61537;=0,05). O grupo G1 apresentou maiores valores de resistência do que G2, exceto no subgrupo CTL e NWA. Houve diferença na técnica de silanização apenas para G1: HWA (25,13±6,83)≥ HA (22,95±7,78)≥ CTL (17,44±7,24)≥ NWA (14,63±8,76). Para G2 não houve diferença entre os subgrupos. Conclui-se que a técnica de silanização interferiu na resistência de união cimento/cerâmica dependendo do material utilizado. A lavagem e secagem com água e ar aquecidos promoveu maior valor de resistência apenas para o cimento dual.


Subject(s)
Ceramics , Dental Porcelain/chemistry , Glass , Silanes/chemistry , Materials Testing , Surface Properties
12.
Dental press j. orthod. (Impr.) ; 18(2): 55-60, Mar.-Apr. 2013. tab
Article in English | LILACS | ID: lil-683184

ABSTRACT

OBJECTIVE: This study compared the clinical performance of orthodontic brackets bonded with Transbond adhesive paste after two priming systems: a two-stage conventional system (acid etching + Transbond XT adhesive primer) and a singlestage self-etching primer (SEP) (Transbond Plus). METHODS: The sample comprised 480 metal brackets bonded to the teeth of 24 consecutive patients treated for 36 to 48 months. A split-mouth design was used for bonding, and both systems were used in each patient. Bracket failure rates for each system were analyzed; and failure causes as reported by the patients and the quadrant of teeth for which brackets failed were recorded. RESULTS: The conventional system group had a failure rate of 5.41%, whereas the rate for SEP was 4.58%. In this group, there were 5 failures (38.4%) in the right maxillary quadrant, 2 (15.4%) in the left maxillary quadrant, 4 (30.8%) in the right mandibular quadrant, and 2 (15.4%) in the left mandibular quadrant. In the SEP group, there were 4 (36.4%) failures in the right maxillary quadrant, 1 (9%) in the left maxillary quadrant, 3 (27.3%) in the right mandibular quadrant, and 3 (27.3%) in the left mandibular quadrant. Results of descriptive statistical analysis and odds ratio did not show any significant differences between rates (p = 0.67). CONCLUSION: The clinical efficiency of SEP was similar to that of the conventional system.


OBJETIVO: o objetivo do presente estudo foi comparar o desempenho clínico da colagem de braquetes ortodônticos com resina Transbond (3M Unitek) associada a dois sistemas adesivos: convencional em duas etapas (ataque ácido + Transbond XT adhesive Primer) e Self-Etching Primer (SEP), em etapa única (Transbond Plus). MÉTODOS: a amostra foi constituída de 480 braquetes metálicos (Victory, 3M Unitek), colados em 24 pacientes, que foram tratados durante um período de 36 a 48 meses. A colagem foi feita por meio do sistema split-mouth, utilizando os dois sistemas de colagem em cada paciente. Foi analisada a taxa de queda dos braquetes para cada sistema de colagem, descrita a causa da queda conforme relato do paciente e a posição dos dentes nas arcadas. RESULTADOS: o sistema adesivo convencional apresentou taxa de queda de 5,41%, enquanto a do SEP foi de 4,58%. O sistema convencional apresentou 5 quedas (38,4%) no quadrante superior direito, 2 (15,4%) no quadrante superior esquerdo, 4 (30,8%) no quadrante inferior direito e 2 (15,4%) no quadrante inferior esquerdo. O SEP apresentou 4 quedas (36,4%) no quadrante superior direito, 1 (9%) no quadrante superior esquerdo, 3 (27,3%) no quadrante inferior direito e 3 (27,3%) no quadrante inferior esquerdo. Por meio da análise estatística descritiva e do teste Odds Ratio, constatou-se que não houve diferença significativa entre essas taxas (p = 0,67). CONCLUSÃO: com base nesses resultados, pode-se concluir que o sistema adesivo SEP apresentou eficácia clínica semelhante à do sistema adesivo convencional.


Subject(s)
Humans , Acid Etching, Dental/methods , Bisphenol A-Glycidyl Methacrylate/chemistry , Dental Bonding/methods , Orthodontic Brackets , Resin Cements/chemistry , Dental Stress Analysis , Equipment Failure Analysis , Materials Testing , Odds Ratio
13.
Braz. dent. j ; 23(1): 22-27, 2012. tab
Article in English | LILACS | ID: lil-618000

ABSTRACT

The aim of this study was to assess, using the DPPH assay, the antioxidant activity of several substances that could be proposed to immediately revert the problems caused by bleaching procedures. The percentage of antioxidant activity (AA percent) of 10 percent ascorbic acid solution (AAcidS), 10 percent ascorbic acid gel (AAcidG), 10 percent sodium ascorbate solution (SodAsS), 10 percent sodium ascorbate gel (SodAsG), 10 percent sodium bicarbonate (Bicarb), Neutralize® (NE), Desensibilize® (DES), catalase C-40 at 10 mg/mL (CAT), 10 percent alcohol solution of alpha-tocopherol (VitE), Listerine® (LIS), 0.12 percent chlorhexidine (CHX), Croton Lechleri (CL), 10 percent aqueous solution of Uncaria Tomentosa (UT), artificial saliva (ArtS) and 0.05 percent sodium fluoride (NaF) was assessed in triplicate by 2,2-diphenyl-1-picryl-hydrazyl-hydrate (DPPH) free radical assay. All substances exhibited antioxidant activity, except for CL. AAcidS, AAcidG and VitE exhibited the highest AA percent (p<0.05). On the contrary, CHX, NE, LIS and NaF showed the lowest AA percent (p<0.05). In conclusion, AAcidS, AAcidG, SodAsS, SodAsG and VitE presented the highest antioxidant activity among substances tested in this study. The DPPH assay provides an easy and rapid way to evaluate potential antioxidants.


O objetivo deste estudo foi avaliar, por meio do DPPH, a atividade antioxidante de substâncias que poderiam ser propostas para reverter de imediato os problemas causados pelos procedimentos de clareamento. A porcentagem de atividade antioxidante (AA por cento) da solução de acido ascórbico 10 por cento (AAcidS), gel de ácido ascórbico a 10 por cento (AAcidG), solução de ascorbato de sódio 10 por cento (SodAsS), gel de ascorbato de sódio 10 por cento (SodAsG), bicarbonato de sódio 10 por cento (Bicarb), Neutralize® (NE), Desensibilize® (DES), catalase C-40 10 mg/mL (CAT), solução alcoólica 10 por cento de alfa-tocoferol (VitE), Listerine® (LIS), clorexidina 0,12 por cento (CHX), CrotonLechleri (CL), solução aquosa 10 por cento de Uncaria Tomentosa (UT), saliva artificial (ArtS) e fluoreto de sódio 0,05 por cento (NaF) foi avaliada em triplicata pelo teste de radicais livres 2,2-diphenyl-1-picryl-hydrazyl-hydrate (DPPH). Todas as substâncias apresentaram atividade antioxidante, exceto a CL. AAcidS, AAcidG e VitE mostraram os maiores valores de AA por cento (p<0,05). Por outro lado, CHX, NE, LIS e NaF mostraram os valores mais baixos de AA por cento (p<0,05). Em conclusão, AAcidS, AAcidG, SodAsS, SodAsG e VitE apresentaram os mais altos valores de atividade antioxidante entre as substâncias testadas. O teste DPPH é um método rápido e fácil para avaliar o potencial antioxidante.


Subject(s)
Humans , Antioxidants/chemistry , Biphenyl Compounds/chemistry , Free Radical Scavengers/chemistry , Picrates/chemistry , Tooth Bleaching/adverse effects , Analysis of Variance , Indicators and Reagents , Spectrophotometry, Ultraviolet , Solutions/chemistry
14.
Rev. odonto ciênc ; 24(4): 414-419, Oct.-Dec. 2009. tab, graf
Article in English | LILACS, BBO | ID: biblio-873970

ABSTRACT

Purpose: To evaluate the effect of the addition of three radiopaque agents to an experimental adhesive on conversion kinetics, flexural strength and radiodensity. Methods: The model adhesive was formulated by mixing 50 wt% Bis-GMA, 25 wt% TEGDMA and 25 wt% HEMA. Barium sulfate, Titanium dioxide and Zirconium in 0.1, 0.2, 0.4, 0.8 and 1.6 wt% were added separately resulting in 15 experimental groups and 1 control group. The conversion kinetics of the model adhesive was evaluated using real time Fourier Transform Infrared Spectroscopy. The flexural tests were performed on 5 specimens (12 × 2 × 2 mm) for each group (total n = 80) in a universal testing machine. The radiodensity was evaluated by using an aluminum step-wedge and VistaScan phosphorous plates radiographs digital system with 0.6 s exposure and focal distance of 40 cm. Results: No statistical difference (P > 0.05) was found in flexural strength among all groups. The values of degree of conversion ranged from 45.51% e 62.46%. All groups showed higher values than 0.54 mm of aluminum for the evaluation of radiopacity. Conclusion: The addition of radiopaquing agents increased the adhesive radiodensity and did not affect its degree of conversion and flexural strength.


Objetivo: Avaliar a influência da adição de três substâncias radiopacificadoras na cinética de conversão, resistência à flexão e radiodensidade de um adesivo experimental. Metodologia: O adesivo foi formulado com 50% de Bis-GMA, 25% TEGDMA e 25% HEMA, em peso. Foram adicionados 0,1%; 0,2%; 0,4%; 0,8%; 1,6%, em peso, de Sulfato de Bário, Óxido de Titânio e Dióxido de Zircônia, totalizando 15 grupos experimentais e um grupo controle. A cinética de polimerização foi avaliada por FTIR em tempo real. O ensaio de miniflexão foi realizado com 5 espécimes (12 × 2 × 2 mm) para cada grupo (n total = 80) em uma máquina de ensaios universal. A radiodensidade foi obtida utilizando um sistema digital com placas de fósforo VistaScan, 0,6 s de exposição e distância focal de 40 cm e os valores foram comparados a uma escala de alumínio. Resultados: Não houve diferença estatisticamente significativa no ensaio de miniflexão entre os grupos (P > 0,05). Os valores de grau de conversão ficaram entre 45,51% e 62,46%, enquanto a radiodensidade foi superior a 0,54 mm de alumínio, sem diferença entre os grupos. Conclusão: O acréscimo das substâncias radiopacificadoras aumentou a radiopacidade do adesivo e não alterou o grau de conversão e a resistência à flexão.


Subject(s)
Dentin-Bonding Agents/chemistry , Dental Materials , Case-Control Studies , Tensile Strength
15.
Journal of Practical Stomatology ; (6)2000.
Article in Chinese | WPRIM | ID: wpr-670799

ABSTRACT

Objective:To evaluate the cytotoxicity of different dental bonding agents to human dental pulp cells. Methods:Four dental bonding agents(Prime & Bond NT,Single Bond,Xeno Ⅲ and iBond) were diluted with the culture medium by a ratio of 1∶1 000,1∶2 000 and 1∶4 000(v/v), and the fourth passage of dental pulp cells were then exposed to agent dilutions for 12, 24 and 48 h respectively, then the morphological changes of pulp cells were observed with microscopy and cytotoxicity was analyzed with modified 3-(4,5-dimethyl-thiazol-2-yl)-2,5-diphenyl-tetrazolium bromide (MTT) assay.Results:There was significant influence of the type of dental bonding agents,exposure time and concentration on the cell morphology. Total-etch system was more toxic than self-etch system.Conclusion:Dental bonding agents are toxic to pulp cells,Single Bond is the strongest cytotoxic agent among the 4 adhesive agents.

SELECTION OF CITATIONS
SEARCH DETAIL